The kidney is made up of about a million tiny units that filter blood, rid the body of undesired waste products while holding back blood cells and valuable proteins, and control the bodys fluid content. Key to each of these units is a structure known the glomerulus, in which podocyte cells wrap themselves tightly around a tuft of capillaries separated only by a thin membrane composed of extracellular matrix, and leave slits between them to build an actual filtration barrier. Podocytes are the target of many congenital or acquired kidney diseases, and they are often harmed by drugs.

To build an in vitro model of the human glomerulus to probe deeper into its function and vulnerabilities to disease and drug toxicities, researchers have been attempting to engineer human stem cells that in theory can give rise to any mature cell type so that they form into functional podocytes. These cell culture efforts, however, so far have failed to produce populations of mature podocytes pure enough as to be useful for modeling glomerular filtration.

A team led by Donald Ingber, Professor of Bioengineering at the Harvard John A. Paulson School of Engineering and Applied Sciences (SEAS) and Founding Director of Harvards Wyss Institute of Biologically Inspired Engineering, now reports a solution to this challenge in Nature Biomedical Engineering, which enables the differentiation of human induced pluripotent stem (iPS) cells into mature podocytes with more than 90 percent efficiency.

Linking the differentiation process with organ-on-a-chip technology pioneered by his team, the researchers went on to engineer the first in vitro model of the human glomerulus, demonstrating effective and selective filtration of blood proteins and podocyte toxicity induced by a chemotherapy drug in vitro.

Ingber is also theJudah Folkman Professor of Vascular Biologyat Harvard Medical School (HMS) and the Vascular Biology Program at Boston Childrens Hospital.

The development of a functional human kidney glomerulus chip opens up an entirely new experimental path to investigate kidney biology, carry out highly personalized modeling of kidney diseases and drug toxicities, and the stem cell-derived kidney podocytes we developed could even offer a new injectable cell therapy approach for regenerative medicine in patients with life-threatening glomerulopathies in the future, said Ingber.

Ingbers team has engineered multiple organs-on-chips that accurately mimic human tissue and organ-level physiology. These platforms are currently being evaluated by the Food and Drug Administration (FDA) as a tool to more effectively study the effects of potential chemical and biological hazards found in foods, cosmetics or dietary supplementsthan existing culture systems or animal models. In 2013, his team developed an organ-on-a-chip microfluidic culture device that modeled the human kidneys proximal tubule, which is anatomically connected to the glomerulus and salvages ions from urinary fluid.

Now, with the teams newly engineered human kidney glomerulus-on-a-chip, researchers also can get in vitro access to the kidneys core filtration mechanisms that are critical for drug clearance and pharmacokinetics, in addition to studying human podocytes at work.

To generate almost pure populations of human podocytes in cell culture, Samira Musah, the studys first author and HMS Deans Postdoctoral Fellow who is working with Ingber at the Wyss Institute, leveraged pieces of the stem cell biologists arsenal, and merged them with snippets taken from Ingbers past research on how cells in the body respond to adhesive factors and physical forces in their tissue environments.

Our method not only uses soluble factors that guide kidney development in the embryo but, by growing and differentiating stem cells on extracellular matrix components that are also contained in the membrane separating the glomerular blood and urinary systems, we more closely mimic the natural environment in which podocytes are induced and mature, said Musah. We even succeeded in inducing much of this differentiation process within a channel of the microfluidic chip, whereby applying cyclical motions that mimic the rhythmic deformations living glomeruli experience due to pressure pulses generated by each heartbeat, we achieve even greater maturation efficiencies.

The complete microfluidic system closely resembles a living, three-dimensional cross-section of the human glomerular wall. It consists of an optically clear, flexible, polymeric material the size of a computer memory chip in which two closely opposed microchannels are separated by a porous, extracellular matrix-coated membrane that corresponds to the kidneys glomerular basement membrane. In one of the membrane-facing channels, the researchers grow glomerular endothelial cells to mimic the blood microvessel compartment of glomeruli. The iPS cells are cultured on the opposite side of the membrane in the other channel that represents the glomerulus urinary compartment, where they are induced to form a layer of mature podocytes that extend long cellular processes through the pores in the membrane and contact the underlying endothelial cells. In addition, the devices channels are rhythmically stretched and relaxed at a rate of one heart beat per second by applying cyclic suction to hollow chambers placed on either side of the cell-lined microchannels to mimic physiological deformations of the glomerular wall.

This in vitro system allows us to effectively recapitulate the filtration of small substances contained in blood into the urinary compartment while retaining large proteins in the blood compartment just like in our bodies, and we can visualize and monitor the damage inflicted by drugs that cause breakdown of the filtration barrier in the kidney, said Musah.

The study was also co-authored by Wyss Institute Core Faculty member George Church, who also is Professor of Genetics at HMS and Professor of Health Sciences and Technology at Harvard and the Massachusetts Institute of Technology (MIT), and who served as a co-mentor of Musah with Ingber. Other authors include Akiko Mammoto and Tadanori Mammoto, who at the time of the study were Instructors in the Vascular Biology Program and Department of Surgery at Boston Childrens Hospital, as well as Thomas Ferrante, Sauveur Jeanty, Kristen Roberts, Seyoon Chung, Richard Novak, Miles Ingram, Tohid Fatanat-Didar, Sandeep Koshy, and James Weaver.

Funding for the study was provided by the Defense Advanced Research Projects Agency (DARPA). Musah was supported by a HMS Deans Postdoctoral Fellowship, Postdoctoral Enrichment Program Award from the Burroughs Wellcome Fund, UNCF-Merck Postdoctoral Fellowship, and an NIH/NIDDK Nephrology Training Grant.